Hangzhou Sanke Electrical Co.,Ltd.
|
Price: | 3.0~5.0 USD |
Payment Terms: | T/T,L/C |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
15W Single Output Switching Power Supply | ||||
Features: High efficiency, high reliability, low cost Universal AC input /full range 100% full load burn-in test Protection: Short circuit /Overload Fixed switching frequency at 37KHz Cooling by free air convection 1 year warranty (CE certificate) Dimensions: 99*97*35mm (L*W*H) | ||||
MODEL | SKK-S-15-5 | SKK-S-15-12 | SKK-S-15-24 | |
OUTPUT | DC Voltage | 5V | 12V | 24V |
Voltage Tolerance | ±2% | ±1% | ±1% | |
Rated Current | 3A | 1.3A | 0.7A | |
Current Range | 0-3A | 0-1.3A | 0-0.7A | |
Rated Power | 15W | 15.6W | 16.8W | |
Ripple & Noise | 50mVp-p | 80mVp-p | 120mVp-p | |
DC Adjustment Range | +10,-5% | ±10% | ±10% | |
Setup, Rise, Hold Time | ||||
INPUT | Voltage Range | 88~264 VAC 47~63Hz selected by switch 120~370 VDC | ||
AC Current | 0.5A/115V 0.25A/230V | |||
Efficiency | 74% | 76% | 78% | |
Inrush Current | Cold start 15A/115VAC 30A/230VAC | |||
Leakage Current | <0.5 mA/240VAC | |||
PROTECTION | Over Load | 110%~150% | ||
Protection: Shut down o/p voltage, re-power on to recover | ||||
Over Voltage | 115%~150% | |||
Protection: Hiccup mode, recovers automatically after fault condition is removed | ||||
ENVIRONMENT | Working Temp., Humidity | -10℃~+60℃;20%~90 %RH | ||
Storage Temp., Humidity | -20℃~+85℃;10%~95%RH | |||
Vibration | 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY | Withstand Voltage | I/P-O/P:1.5KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC | ||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ | |||
STANDARD | Safety Standard | Design refer to GB4943,UL60950,EN60950 | ||
EMC Standard | Design refer to EN55022,EN61000-3-2,EN61000-3-3,EN55024 | |||
OTHERS | Weight | 0.30Kg | ||
Packing | 48pcs/15Kg/0.027CBM | |||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |