Hangzhou Sanke Electrical Co.,Ltd.
|
Price: | 7.0~9.0 USD |
Payment Terms: | T/T,L/C |
Place of Origin: | Zhejiang, China (Mainland) |
![]() |
|
Add to My Favorites | |
HiSupplier Escrow |
60W Single Output Switching Power Supply | |||||
Features: High efficiency, high reliability, low cost AC input range selected by switch 100% full load burn-in test Protection: Short circuit /Overload Fixed switching frequency at 50KHz Cooling by free air convection 1 year warranty (CE certificate) Dimensions: 159*97*38mm (L*W*H) | |||||
MODEL | SKK-S-60-5 | SKK-S-60-12 | SKK-S-60-15 | SKK-S-60-24 | |
OUTPUT | DC Voltage | 5V | 12V | 15V | 24V |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | |
Rated Current | 12A | 5A | 4A | 2.5A | |
Current Range | 0-12A | 0-5A | 0-4A | 0-2.5A | |
Rated Power | 60W | 60W | 60W | 60W | |
Ripple & Noise | 80mVp-p | 90mVp-p | 90mVp-p | 110mVp-p | |
DC Adjustment Range | +10,-5% | ±10% | ±10% | ±10% | |
Setup, Rise, Hold Time | 200ms,50ms,20ms at full load | ||||
INPUT | Voltage Range | 88~132 VAC/176~264 VAC 47~63Hz selected by switch 240~370 VDC | |||
AC Current | 2A/115V 1A/230V | ||||
Efficiency | 75% | 78% | 78% | 80% | |
Inrush Current | Cold start 30A/115VAC 60A/230VAC | ||||
Leakage Current | <3.5 mA/240VAC | ||||
PROTECTION | Over Load | 110%~150% | |||
Protection: Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | Working Temp., Humidity | -10℃~+60℃;20%~90 %RH | |||
Storage Temp., Humidity | -20℃~+85℃;10%~95%RH | ||||
Vibration | 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | ||||
SAFETY | Withstand Voltage | I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ | ||||
STANDARD | Safety Standard | Design refer to GB4943,UL60950,EN60950 | |||
EMC Standard | Design refer to EN55022,EN61000-3-2,EN61000-3-3,EN55024 | ||||
OTHERS | Weight | 0.46Kg | |||
Packing | 48pcs/22.5Kg/0.042CBM | ||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |